04 Power Options
Evercam fixed-position systems can support mains, solar, mains-assisted and generator-backed deployments. The final design depends on site conditions, system load and required autonomy.
Configuration comparison
Configuration | Typical use | Power arrangement | Continuity |
|---|---|---|---|
Mains | Sites with reliable permanent power | 110-240V AC through the approved external PSU | Internal battery supports controlled shutdown only |
Solar | Remote sites without permanent power | Solar array charging the external Battery Box | Battery-backed operation |
Mains-assisted | Sites requiring extended continuity | Mains plus Battery Box and AC/DC charger | Continued operation during suitable outages |
Generator-backed | Temporary or remote sites | Generator charging the Battery Box | Battery-supported operation between charging periods |
Mains power
110-240V AC terminated to an external AC-to-DC power supply, with 13V DC connected to the control enclosure.
Mains termination must be completed by a suitably competent person. Isolate the AC supply before connecting, disconnecting or servicing equipment.
Internal safe-shutdown battery
The battery inside the main control enclosure is intended to support controlled shutdown of recording hardware. It is not a whole-system backup and should not be described as providing continued camera operation.
Evercam Battery Box / Solar Power Add-on
The Battery Box is a separately purchased external energy-storage system. The Operations reference specifies:
Victron 100/20 Smart MPPT solar charge controller.
Victron SmartShunt battery monitor.
Two 105Ah LiFePO4 batteries.
30A AC/DC charger for mains- or generator-assisted charging.
Umbilical cable to the main control box.
IP55 enclosure.
The reference recommends at least 600W of total solar-panel capacity. Final sizing must consider deployment location, seasonal solar yield, system load and required autonomy.
The LiFePO4 configuration replaces the older three-battery GEL design. A minimum of 600 W total solar-panel capacity is approved for public guidance.